MOSAIC is an innovative, modular, and configurable safety controller designed to streamline the management of machinery or plant safety functions. By reducing the need for multiple devices and extensive wiring, MOSAIC simplifies control panel construction and enables a tamper-proof configuration through an intuitive graphic interface. It supports diverse safety sensors, including light curtains, emergency stops, magnetic switches, and encoders for speed control, ensuring comprehensive safety across applications.
MOSAIC’s project reporting provides essential safety performance data, including PFH, DCavg, and MTTFd values per EN 13849-1 and EN 62061 standards.
To download the Catalogue Page, click on the link below:
Mosaic M1 (Standard Master Unit)
Safety level: PL e
Safety inputs: 8 digital inputs
Safety level (SIL / PL): SIL 3 – SILCL 3 – PL e – Cat. 4
Signalling: LEDs indication for operating status and fault diagnosis. LED indication of the: inputs, OSSD outputs, reset request and status outputs condition
Safety output type: 2 OSSD PNP (400 mA at 24 VDC) with protection against short circuit, overload and reverse polarity
Connections: Removable terminal blocks, screw contacts
Safety outputs: 2 OSSD pairs (400 mA)
Status outputs: 2 PNP (100 mA)
Test outputs: 4
MSC connector provided: No
Connection with MSC BUS: Yes
Start/Restart inputs and EDM: 2
Housing for MCM: Yes
USB input: Yes
Mosaic M1S (Enhanced Master Unit)
Safety level: PL e
Safety inputs: 8 digital inputs
Safety level (SIL / PL): SIL 3 – SILCL 3 – PL e – Cat. 4
Signalling: LEDs indication for operating status and fault diagnosis. LED indication of the: inputs, OSSD outputs, reset request and status outputs condition
Safety output type: 4 single OSSD, or 2 pairs (PNP – 400mA at 24 VDC) with protection against short circuit, overload and reverse polarity
Connections: Removable terminal blocks, screw contacts
Safety outputs: 4 single OSSD, or 2 pairs (400 mA)
Status outputs: 4 PNP (100 mA)
Test outputs: 4
MSC connector provided: No
Connection with MSC BUS: Yes
Start/Restart inputs and EDM: 4
Housing for MCM: Yes
USB input: Yes
Mosaic M1S COM (Enhanced Master Unit)
Safety level: PL e
Safety inputs: 8 digital inputs
Safety level (SIL / PL): SIL 3 – SILCL 3 – PL e – Cat. 4
Signalling: LEDs indication for operating status and fault diagnosis. LED indication of the: inputs, OSSD outputs, reset request and status outputs condition. Specific LED indicator for the Fieldbus
Safety output type: 4 single OSSD, or 2 pairs (PNP – 400mA at 24 VDC) with protection against short circuit, overload and reverse polarity
Connections: Removable terminal blocks, screw contacts
Safety outputs: 4 single OSSD, or 2 pairs (400 mA)
Status outputs: 4 PNP (100 mA)
Test outputs: 4
MSC connector provided: No
Connection with MSC BUS: Yes
Start/Restart inputs and EDM: 4
Housing for MCM: Yes
USB input: Yes
Mosaic MI8O2 (Expansion Unit)
Safety level: PL e
Safety inputs: 8 digital inputs
Safety level (SIL / PL): SIL 3 – SILCL 3 – PL e – Cat. 4
Signalling: LEDs indication for operating status and fault diagnosis. LED indication of the: inputs, OSSD outputs and status outputs condition
Safety output type: 2 OSSD PNP (400 mA at 24 VDC) with protection against short circuit, overload and reverse polarity
Connections: Removable terminal blocks, screw contacts
Safety outputs: 2 OSSD pairs (400 mA)
Status outputs: 2 PNP (100 mA)
Test outputs: 4
MSC connector provided: Yes
Connection with MSC BUS: Yes
Start/Restart inputs and EDM: 2
Mosaic MI8O4 (Expansion Unit)
Safety level: PL e
Safety inputs: 8 digital inputs
Safety level (SIL / PL): SIL 3 – SILCL 3 – PL e – Cat. 4
Signalling: LEDs indication for operating status and fault diagnosis. LED indication of the: inputs, OSSD outputs and status outputs condition
Safety output type: 4 single OSSD, or 2 pairs (PNP – 400mA at 24 VDC) with protection against short circuit, overload and reverse polarity
Connections: Removable terminal blocks, screw contacts
Safety outputs: 4 single OSSD, or 2 pairs (400 mA)
Status outputs: 4 PNP (100 mA)
Test outputs: 4
MSC connector provided: Yes
Connection with MSC BUS: Yes
Start/Restart inputs and EDM: Up to 4
Mosaic MO4L (Expansion Unit)
Safety level: PL e
Safety level (SIL / PL): SIL 3 – SILCL 3 – PL e – Cat. 4
Signalling: LEDs indication for operating status and fault diagnosis. LED indication of the: OSSD outputs, reset request and status outputs condition
Safety output type: 4 single OSSD, or 2 pairs (PNP – 400mA at 24 VDC) with protection against short circuit, overload and reverse polarity
Connections: Removable terminal blocks, screw contacts
Safety outputs: 4 single OSSD, or 2 pairs (400 mA)
Status outputs: 4 PNP (100 mA)
Test outputs: 4
MSC connector provided: Yes
Connection with MSC BUS: Yes
Start/Restart inputs and EDM: Up to 4
Mosaic MI8 (Expansion Unit)
Safety level: PL e
Safety inputs: 8 digital inputs
Safety level (SIL / PL): SIL 3 – SILCL 3 – PL e – Cat. 4
Signalling: LEDs indication for operating status and fault diagnosis. LED indication of the inputs condition
Connections: Removable terminal blocks, screw contacts
Test outputs: 4
MSC connector provided: Yes
Connection with MSC BUS: Yes
Mosaic MI16 (Expansion Unit)
Safety level: PL e
Safety inputs: 16 digital inputs
Safety level (SIL / PL): SIL 3 – SILCL 3 – PL e – Cat. 4
Signalling: LEDs indication for operating status and fault diagnosis. LED indication of the inputs condition
Connections: Removable terminal blocks, screw contacts
Test outputs: 4
MSC connector provided: Yes
Connection with MSC BUS: Yes
Mosaic MI12T8 (Expansion Unit)
Safety level: PL e
Safety inputs: 12 digital inputs
Safety level (SIL / PL): SIL 3 – SILCL 3 – PL e – Cat. 4
Signalling: LEDs indication for operating status and fault diagnosis. LED indication of the inputs condition
Connections: Removable terminal blocks, screw contacts
Test outputs: 8
MSC connector provided: Yes
Connection with MSC BUS: Yes
Mosaic M1S RV (Enhanced Master Unit ATEX Standards Compliant)
Safety level: PL e
Safety inputs: 8 digital inputs (4 mA max.)
Safety level (SIL / PL): SIL 3 – SILCL 3 – PL e – Cat. 4
Signalling: LEDs indication for operating status and fault diagnosis. LED indication of the: inputs, OSSD outputs, reset request and status outputs condition
Safety output type: 4 single OSSD, or 2 pairs (PNP – 400mA at 24 VDC) with protection against short circuit, overload and reverse polarity
Connections: Removable terminal blocks, screw contacts
Safety outputs: 4 single OSSD, or 2 pairs (400 mA)
Status outputs: 4 PNP (100 mA)
Test outputs: 4
MSC connector provided: No
Connection with MSC BUS: Yes
Start/Restart inputs and EDM: 4 (4 mA max.)
Housing for MCM: Yes
USB input: Yes
To download the Catalogue Page, click on the link below:
M1 Standard Master Unit
M1S Enhanced Master Unit
MO2 / MO4 / MO4L Output Units
MI8 / MI16 / MI12T8 Input Units
MI8O2 / MI8O4 Input/Output Units
MOS8 / MOS16 Non-Safety Output Units
MBx Field-Bus Units
Supports various fieldbus protocols including Profibus DP, DeviceNET, CANopen, EthernetIP, EtherCAT, Profinet, Modbus RTU, and Modbus TCP/IP. Interface modules (MCT1 and MCT2) connect remote expansions via the MSC bus.
MA4 Analog Input Expansion
Four isolated analog channels supporting applications requiring analog sensor inputs like load cells, pressure switches, temperature sensors, etc.
MR2 / MR4 Safety Relay Output Units
MOR4 / MOR4S8 Safety Relay Output Units
MV0 / MV1 / MV2 Speed Monitoring Units
Safety speed monitoring up to PL e for zero, maximum, and directional speed control.
Mosaic Accessories
Please fill out the form below, and a member of our team will contact you to discuss your needs and answer any questions.
Type part numbers or product names below to get started.