 | EOS4 |
 | Type 4 integrated compact light curtain |
 |
 | JANUS |
 | Type 4 Muting light curtain |
 |
 | JANUS LR |
 | Heavy Duty Long Range Type 4 light curtain |
 |
 | JANUS M TRX |
 | Type 4 light grid with Muting and retro-reflector |
 |
 | EOS2 |
 | Type 2 integrated compact light curtain |
 |
 | PHARO |
 | Type 3 laser scanner |
 |
 | VISION MXL |
 | Type 2 light curtain with integrated Muting |
 |
 | METRON |
 | measurement and control light curtain |
 |
 | ADSR1 |
 | Light curtain module Type4/PLe |
 |
 | ADSRT |
 | Two-hand control module Cat.4/PLe |
 |
 | ADSRM |
 | Light curtain module Type4/PLe with muting function |
 |
 | AUSX |
 | Control unit for Type2/PLd safety photocells |
 |
 | AUSXM |
 | Muting control unit for Type2/PLd safety photocells |
 |
 | AU S-TWIN |
 | Type 2 control unit |
 |
 | A-CI5 |
 | AS-i Safety at Work interface |
 |
|
|
AU S-TWIN


|
TYPE 2 SAFETY CONTROL UNIT
New control unit which, used in conjunction with the safety barriers of the series Argolux AS, Minerva or Ulisse, forms a type 2 photoelectric safety system for the protection of workers exposed to risks arising from the use of hazardous machines. It's designed in compliance with the European Standard EN 61496-1 and the International Standard IEC 61496-1.
Conforming to:
- 98/37/EEC "Directive on Machines" - 89/336/EEC "Electromagnetic Compatibility Directive" - 73/23/EEC "Low Voltage Directive" - EN 61496-1-2 and IEC 61496-1-2 "Electrosensitive protection devices"
|
Model | AU S-TWIN | Ordering Code | 1201708 |
[Technical Detail Table]
Technical Specifications:
It can control and be connected to: - 1 or 2 barriers of the series Argolux AS - 1,2,3 or 4 photocells of the series Minerva or Ulisse - 1 barrier of the series Argolux AS and either 1 or 2 photocells of the series Minerva or Ulisse - Power supply 24 Vcc ±20% - Selectable (dip-switch) manual or automatic reset - Perfect mechanical and electrical interchangeability with the control unit AU S3 (same housing and same connection diagram) - Feedback input for the control of the final switching devices (FSD) - Correct alignment and fault diagnosis indicator Led's - 2 NO and 1 NC outputs with safety relays using forced guide relays - Provision for fastening to a bar according to Standard EN 50022-35 - Terminal blocks connection
DISCLAIMER
The products described in this catalogue can be modified by Reer SpA without prior notice.
All the information and examples concerning applications are given as a pure indication. Reer does not assume any responsibility in that sense.
Concerning your application, refer only to its detailed risk analysis; concerning the use of Reer products, refer only to their user manual and contact Reer directly in any case of doubt.
| |
|
 |