 | EOS4 |
 | Type 4 integrated compact light curtain |
 |
 | JANUS |
 | Type 4 Muting light curtain |
 |
 | JANUS LR |
 | Heavy Duty Long Range Type 4 light curtain |
 |
 | JANUS M TRX |
 | Type 4 light grid with Muting and retro-reflector |
 |
 | EOS2 |
 | Type 2 integrated compact light curtain |
 |
 | PHARO |
 | Type 3 laser scanner |
 |
 | VISION MXL |
 | Type 2 light curtain with integrated Muting |
 |
 | METRON |
 | measurement and control light curtain |
 |
 | ADSR1 |
 | Light curtain module Type4/PLe |
 |
 | ADSRT |
 | Two-hand control module Cat.4/PLe |
 |
 | ADSRM |
 | Light curtain module Type4/PLe with muting function |
 |
 | AUSX |
 | Control unit for Type2/PLd safety photocells |
 |
 | AUSXM |
 | Muting control unit for Type2/PLd safety photocells |
 |
 | A-CI5 |
 | AS-i Safety at Work interface |
 |
|
|
AUSX


|
TYPE 2 CONTROL UNIT / PLd
Type 2 control unit to which it is possible to connect from 1 to 4 safety photocells of the Ilion or Ulisse series, thus forming a Type 2 ESPE having a two-channel relay output and the start/restart interlock and FSD monitoring safety functions.
Conforming to:
- 2006/42/CE Machinery Directive - 2004/108/CE Electromagnetic Compatibility Directive (EMC) - 2006/95/CE Low Voltage Directive (LVD) - IEC/EN 61496-1 Ed. 2.1 Safety of machinery - Electro-sensitive protective equipment- General requirements and tests - IEC/TS 61496-2 Ed. 2 Safety of machinery- Electro-sensitive protective equipment – Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices - EN ISO 13849-1 Safety of machinery – Safety-related parts of control systems – Part 1: General principles for design. - IEC/EN 62061 Safety of machinery – Functional safety of safety-related electrical, electronic and programmable electronic control systems - IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems. - UL (C+US) for USA and Canada - ANSI / UL 1998 Software in Programmable Components.
|
Model | AUSX | Ordering Code | 1201710 |
[Technical Detail Table]
Technical Specifications:
- Up to 4 safety photocells can be connected - Periodic self test - Power supply 24 Vcc ± 20% - Selectable manual or automatic restart - Monitored restart contact - 2 NO outputs with safety relays using forced guide contacts - 1 pnp ´output status´ signalisation output - Beams status and fault diagnosis indicator Leds - Feedback input for the control of the machine´s final switching devices (FSD) - Box width 22,5 mm - Provision for fastening to a bar according to Standard EN 50022-35 - Connections with terminal blocks
DISCLAIMER
The products described in this catalogue can be modified by Reer SpA without prior notice.
All the information and examples concerning applications are given as a pure indication. Reer does not assume any responsibility in that sense.
Concerning your application, refer only to its detailed risk analysis; concerning the use of Reer products, refer only to their user manual and contact Reer directly in any case of doubt.
| |
|
 |