| EOS4 |
| Type 4 integrated compact light curtain |
|
| JANUS |
| Type 4 Muting light curtain |
|
| JANUS LR |
| Heavy Duty Long Range Type 4 light curtain |
|
| JANUS M TRX |
| Type 4 light grid with Muting and retro-reflector |
|
| EOS2 |
| Type 2 integrated compact light curtain |
|
| PHARO |
| Type 3 laser scanner |
|
| VISION MXL |
| Type 2 light curtain with integrated Muting |
|
| METRON |
| measurement and control light curtain |
|
| ADSR1 |
| Light curtain module Type4/PLe |
|
| ADSRE4 ADSRE4C |
| Emergency stop module Cat.4/PLe |
|
| ADSRT |
| Two-hand control module Cat.4/PLe |
|
| ADSRM |
| Light curtain module Type4/PLe with muting function |
|
| AUSX |
| Control unit for Type2/PLd safety photocells |
|
| AUSXM |
| Muting control unit for Type2/PLd safety photocells |
|
| A-CI5 |
| AS-i Safety at Work interface |
|
|
|
ADSRE4 ADSRE4C
|
SAFETY RELAY MODULE FOR EMERGENCY STOP CAT.4 / PLe
Safety relay module, category 4 / PL e for emergency stop. Model ADSRE4 with selectable operation: automatic restart or manual restart (not monitored). Model ADSRE4C with monitored manual restart.
Conforming to:
- 2006/42/CE Machinery Directive - 2004/108/CE Electromagnetic Compatibility Directive (EMC) - 2006/95/CE Low Voltage Directive (LVD) - EN ISO 13849-1 Safety of machinery – Safety-related parts of control systems – Part 1: General principles for design. - UL (C+US) for USA and Canada
|
[Ordering Code List]
[Technical Detail Table]
Technical Specifications:
- Power supply 24 V AC/DC - ADSRE4C With monitoring of the start button - ADSRE4 For automatic start (without reset monitoring) - 3 NO outputs/ 1 auxiliary NC using forced guide contacts - Box width 22,5 mm - Rail fastening according to EN 50022 standard - Connections with terminal blocks
DISCLAIMER
The products described in this catalogue can be modified by Reer SpA without prior notice.
All the information and examples concerning applications are given as a pure indication. Reer does not assume any responsibility in that sense.
Concerning your application, refer only to its detailed risk analysis; concerning the use of Reer products, refer only to their user manual and contact Reer directly in any case of doubt.
| |
|
|