| EOS4 |
| Type 4 integrated compact light curtain |
|
| JANUS |
| Type 4 Muting light curtain |
|
| JANUS LR |
| Heavy Duty Long Range Type 4 light curtain |
|
| JANUS M TRX |
| Type 4 light grid with Muting and retro-reflector |
|
| EOS2 |
| Type 2 integrated compact light curtain |
|
| PHARO |
| Type 3 laser scanner |
|
| VISION MXL |
| Type 2 light curtain with integrated Muting |
|
| METRON |
| measurement and control light curtain |
|
| ADSR1 |
| Light curtain module Type4/PLe |
|
| ADSRT |
| Two-hand control module Cat.4/PLe |
|
| ADSRM |
| Light curtain module Type4/PLe with muting function |
|
| AUSX |
| Control unit for Type2/PLd safety photocells |
|
| AUSXM |
| Muting control unit for Type2/PLd safety photocells |
|
| A-CI5 |
| AS-i Safety at Work interface |
|
|
|
ADSRM
|
TYPE 4 / PL e SAFETY RELAY FOR LIGHT CURTAINS WITH MUTING FUNCTION
Type 4 Safety Interface which, connected to the two safe static outputs of the Admiral or Vision light curtains, offers 2 NO safety relay outputs, plus optional features as the manual restart, the final switching devices monitoring (FSD) and the 2-sensor sequentioal logic muting function.
Conforming to:
- 2006/42/CE Machinery Directive - 2004/108/CE Electromagnetic Compatibility Directive (EMC) - 2006/95/CE Low Voltage Directive (LVD) - IEC/EN 61496-1 Ed. 2.1 Safety of machinery - Electro-sensitive protective equipment- General requirements and tests - IEC/TS 61496-2 Ed. 2 Safety of machinery- Electro-sensitive protective equipment – Part 2:Particular requirements for equipment using Active Optoelectronic Protective Devices - EN ISO 13849-1 Safety of machinery – Safety-related parts of control systems – Part 1: General principles for design. - IEC/EN 62061 Safety of machinery – Functional safety of safety-related electrical, electronic and programmable electronic control systems - IEC 61508 Functional safety of electrical/electronic/ programmable electronic safety-related systems. - UL (C+US) for USA and Canada - ANSI / UL 1998 Software in Programmable Components.
|
[Technical Detail Table]
Technical Specifications:
- Power supply 24 Vcc ± 20% - Selectable manual or automatic restart - Monitored restart contact - 2 NO outputs with safety relays using forced guide contacts - Inputs and outputs status and fault diagnosis indicator Leds - Feedback input for the control of the machine´s final switching devices (FSD) - 2-sensors sequential Muting function - Muting enable input - Override functin with 2 selectable operating modes (hold to run and impulse) - Box width 35 mm - Provision for fastening to a bar according to Standard EN 50022-35 - Connections with terminal blocks
DISCLAIMER
The products described in this catalogue can be modified by Reer SpA without prior notice.
All the information and examples concerning applications are given as a pure indication. Reer does not assume any responsibility in that sense.
Concerning your application, refer only to its detailed risk analysis; concerning the use of Reer products, refer only to their user manual and contact Reer directly in any case of doubt.
| |
|
|