| EOS4 |
| Type 4 integrated compact light curtain |
|
| JANUS |
| Type 4 Muting light curtain |
|
| JANUS LR |
| Heavy Duty Long Range Type 4 light curtain |
|
| JANUS M TRX |
| Type 4 light grid with Muting and retro-reflector |
|
| EOS2 |
| Type 2 integrated compact light curtain |
|
| PHARO |
| Type 3 laser scanner |
|
| VISION MXL |
| Type 2 light curtain with integrated Muting |
|
| METRON |
| measurement and control light curtain |
|
| ADSR1 |
| Light curtain module Type4/PLe |
|
| ADSRT |
| Two-hand control module Cat.4/PLe |
|
| ADSRM |
| Light curtain module Type4/PLe with muting function |
|
| AUSX |
| Control unit for Type2/PLd safety photocells |
|
| AUSXM |
| Muting control unit for Type2/PLd safety photocells |
|
| A-CI5 |
| AS-i Safety at Work interface |
|
|
|
PHARO
|
TYPE 3 - SIL 2 SAFETY LASER SCANNER
Safety Laser Scanner, suitable for the protection of workers exposed to risks arising from the use of hazardous machines and automated guidance vehicles (AGVs). Pharo creates horizontal or vertical protection areas through programming or self-teaching, up to an amplitude of 190°
See Pharo´s own site in English
Presentacion de Pharo en Espanol
Conforming to:
- 98/37/EEC Machine Directive - 89/336/EEC Electromagnetic Compatibility Directive - 73/23/EEC Low Voltage Directive - EN 61496-1 and IEC 61496-1-3 Electrosensitive protection devices - IEC 61508 Functional Safety of Electric and Electronic Programmable Devices
|
Configuration:
4 area programming modes: - graphic, through the computer mouse - numeric, through the input of coordinates - file transfer from PC or other peripherals - through connector transfer from another Pharo device, thanks to the memory module
Available Model: 1
- Version with 2 safety and 2 warning zones, programmable and selectable.
Model | PHR 332 | Ordering Code | 1350041 |
[Technical Detail Table]
Technical Specifications:
- Scanning plane of 190° - Safety area max. scanning distance: 4 metres - Warning area max. scanning distance: 15 metres - Max. resolution: 30mm at 4 m - RS 232 serial interface for configuration and data transfer - Automatic, manual or delayed manual restart, selectable - 2 PNP solid state safety outputs, protected against short circuit - 1 PNP solid state signal output for area status and optics contamination - Diagnostics and signal LEDs and display - Detailed self-diagnosis through serial interface - Connections through screw-connectors - Die-cast aluminium body - Distinct users access protected by passwords
DISCLAIMER
The products described in this catalogue can be modified by Reer SpA without prior notice.
All the information and examples concerning applications are given as a pure indication. Reer does not assume any responsibility in that sense.
Concerning your application, refer only to its detailed risk analysis; concerning the use of Reer products, refer only to their user manual and contact Reer directly in any case of doubt.
| |
|
|